Air-to-water heat pump underfloor heating in Ireland: 35°C design & SEAI grants

An air-to-water heat pump reaches its highest seasonal efficiency (SCOP 3.8 to 4.3.

Free, no obligation. One vetted local installer prices your floor — never shared with a calling list.

Flow temperature vs heat pump efficiency (SCOP)

Heat emitter typeDesign flow temperature (at -3°C outside)Typical heat pump SCOPCost per kWh of heat (at 34.4c/kWh elec)
Wet underfloor heating in 50mm liquid screed (150mm pipe centres)32°C–35°C4.0 – 4.38.0c – 8.6c / kWh
Low-profile 15mm–18mm retrofit overlay (100mm–125mm centres)35°C–38°C3.7 – 4.08.6c – 9.3c / kWh
Oversized low-temperature K2/K3 radiators42°C–45°C3.2 – 3.59.8c – 10.7c / kWh
Standard high-temperature radiators50°C–55°C2.6 – 2.911.9c – 13.2c / kWh

Every 1°C reduction in your heat pump's water flow temperature improves compressor efficiency by roughly 2.5% to 3%. Because a heated floor has 8 to 10 times the surface area of wall radiators, it keeps your rooms at 20°C–21°C while circulating lukewarm 35°C water.

2026 SEAI Heat Pump & Central Heating grant breakdown

SEAI Grant Component (Pre-2021 Homes)House GrantApartment GrantKey Technical Requirement
Air-to-Water / Ground-Source Heat Pump Unit€6,500€4,500Home must achieve Post-Works Heat Loss Indicator (HLI) ≤ 2.0 W/K/m²
Renewable Heat Bonus (replacing fossil boiler)€4,000€4,000Applies when removing an existing oil, gas or solid-fuel central heating system
Central Heating Grant (Underfloor Heating / Radiators)Up to €2,000Up to €1,000Covers installing new wet underfloor heating or low-temp heat pump radiators
Boiler Scrappage BonusUp to €2,000Up to €2,000Subject to SEAI scheme eligibility and prior approval before works start
Maximum Combined SEAI Heat Pump PackageUp to €14,500Up to €11,500Plus €200 towards independent Technical Assessment & €50 post-works BER

Important: Underfloor Heating Installation Ireland (underfloorheatinginstallation.ie) is an independent installation introduction service, not SEAI or a government agency. All SEAI grant applications must be approved before works commence on site.

Commissioning a heat pump manifold: avoiding short-cycling

  • No manifold blending valve on direct heat pump feeds: Unlike a 70°C gas boiler, a heat pump operates on weather compensation and sends 28°C–38°C water straight into the manifold. Fitting an unnecessary thermostatic mixing valve restricts flow rate and forces the heat pump to run hotter than needed.
  • Minimum open loop volume & micro-zoning care: Over-zoning every tiny hallway with closed actuators can starve an inverter heat pump of minimum water flow (typically 12–18 L/min) during defrost and low-load cycles. Installers leave the main open-plan kitchen/living zone actuator-free (controlled directly by the heat pump's weather-compensation curve) or fit a small 50L–100L buffer vessel / volumiser.
  • Pipe spacing for 35°C design: Living areas are clipped at 150mm centres (delivering ~55–65 W/m² at 35°C flow), while bathrooms and glazed sunrooms are tightened to 100mm centres so no supplementary towel radiator is needed for space heating.

Get your underfloor heating priced in 4 quick taps

Tell us about your floor and heat source. Your request goes to one vetted underfloor heating installer covering your county, who rings you back to discuss pipe spacing, manifold zones and screed depth before giving a written quote.

What type of underfloor heating job is it?

Pick the closest match — your local installer will confirm the exact spec.

By sending, you agree to Underfloor Heating Installation Ireland passing your details to one vetted underfloor heating installer covering your county so they can contact you with a quote. Privacy notice

Underfloor heating installation guides & specifications

Detailed Irish engineering & cost guides covering pipe spacing, manifold balancing, 15mm retrofit overlays, 35°C heat pump commissioning and floor coverings.

More technical resources: Liquid screed for underfloor heating · All guides & calculator hub · Technical trade glossary (A–Z) · Frequently asked questions · All 26 counties covered

Heat pump UFH: common questions

What HLI score does my house need for the SEAI heat pump and underfloor heating grant?

SEAI requires a Heat Loss Indicator (HLI) of 2.0 W/K/m² or lower (or up to 2.3 W/K/m² if additional fabric upgrades such as attic or wall insulation are completed first, as verified by an SEAI Registered Technical Advisor).

Should I turn heat pump underfloor heating off at night?

No — on a well-insulated heated slab fed by an air-to-water heat pump, turning the heating completely off overnight forces the compressor to work hard at maximum output in the coldest morning air. Instead, use a gentle 1.5°C–2°C night setback (or slight night-rate pre-charge of the slab between 02:00 and 05:00 on a smart EV/night tariff) while letting weather compensation hold a steady temperature.

Can an air-to-water heat pump feed underfloor heating downstairs and radiators upstairs?

Yes — either by sizing upstairs K2/K3 radiators to run at the same 38°C–42°C flow temperature as the floor (simplest and highest SCOP), or by using a two-zone kit where upstairs radiators receive 45°C–48°C water and the downstairs manifold blends down to 35°C.

Underfloor heating installation across all 26 counties

Every quote request is routed to one vetted underfloor heating installer covering your county — from Dublin, Cork, Galway and Limerick to Kildare, Meath, Wicklow, Wexford, Louth, Kerry, Clare, Waterford and Donegal. Pick your county for local housing, heating and radon figures. View full 26-county directory →

Ready to price your underfloor heating installation?

Four quick taps and your phone number. One vetted underfloor heating installer covering your county rings you with a clear written quote.